← Search all jobs

Senior Director, Data Center Design & Engineering – AI Data Centers

CleanSpark

Listing collected from CleanSpark's career site. NextChapter is independent of CleanSpark.

Remote (US) · $200k–$250k a year · Posted November 12, 2026

Will your résumé get you an interview here?

Drop your résumé and see in seconds how well it matches what CleanSpark asks for. Free, no account needed.

Just laid off? Start here: a plan for the first weeks

See every open role at CleanSpark

More in Financial Services & Banking · Data & Analytics jobs

More roles at CleanSpark

Similar jobs

Data & Analytics jobs in the rankings

How AI is used in this kind of work

AI use among architectural and engineering managers is little observed so far. Measured exposure for architectural and engineering managers: 3% (little observed).

Share of this job’s tasks that AI is already used for at work, from real usage. It is not a forecast of job loss, and a low number means no use seen yet. Source: Anthropic Economic Index.

Check how this applies to your own job

Skills this job asks for

Say which you have and which you want to build. We use it to match you to jobs like this one.

About the job

CleanSpark (Nasdaq: CLSK), is a market-leading data center developer with a proven track record of success. We control a portfolio of more than 1.8 GW of power, land, and data centers across the United States powered by globally competitive energy prices. Sitting at the intersection of Bitcoin, energy, operational excellence, and capital stewardship, we optimize our infrastructure to deliver superior returns to our shareholders. Monetizing low-cost, high reliability energy by producing a global emerging critical resource – compute – positions us to prosper in an ever-changing world.

Visit our website at www.cleanspark.com.

Key Responsibilities

Own and maintain CleanSpark’s AI data center engineering standards, Basis of Design (BoD), and design criteria across electrical, mechanical, civil, structural, controls, telecom, and site infrastructure disciplines

Define and approve system architecture for medium-voltage and low-voltage electrical distribution, generation and backup power, UPS, and mechanical cooling (air and liquid) for high-density AI/HPC loads, including redundancy and resilience targets (e.g., N, N+1, 2N) and associated trade-offs

Lead engineering interfaces with utilities and substation owners: load studies, interconnection requirements, substation and switchyard design, protection and coordination, metering, and energization sequencing in support of path-to-power planning

Provide technical direction to the Director, Data Center Design and external design consultants; review and approve technical studies, calculations, single-line diagrams, equipment selections, and design deliverables at each stage gate

Lead constructability, value engineering, and design-for-schedule reviews with Construction and Pre-Construction; resolve technical issues, RFIs, and design conflicts that exceed consultant or project-team authority

Own the owner-side commissioning program: define commissioning scope and levels, approve commissioning agents and test scripts, witness integrated systems testing, and sign off on energization and turnover readiness

Lead operational readiness from an engineering standpoint: handover documentation, as-builts, O&M requirements, spare parts and maintainability criteria, and alignment of design intent with Operations’ requirements

Evaluate and recommend equipment vendors, long-lead procurement specifications, and standard equipment platforms; support procurement with technical bid evaluations and scopes of work

Assess engineering risk across the portfolio; identify design, power, cooling, and integration risks early and drive mitigation into standards and project plans

Support tenant and customer technical requirements, including design review responses, change evaluations, and technical representation in customer and partner forums

Drive standardization and repeatability across sites so designs scale across the portfolio with predictable cost, schedule, and performance

Build and mentor the in-house engineering team; define roles, technical competencies, and development paths as the organization grows

Provide clear technical recommendations and updates to project and executive leadership

This role requires professionalism, respect, strong communication, and the ability to work well with others in a team-oriented, inclusive environment.

Required Qualifications

Bachelor’s degree in Electrical Engineering, Mechanical Engineering, or a closely related engineering discipline

15+ years of progressive experience in the design and engineering of data center, mission-critical, or large-scale power and industrial facilities, including at least 5 years in a senior technical leadership role

Deep working knowledge of data center electrical infrastructure (MV/LV distribution, generation, UPS, protection and coordination) and mechanical infrastructure (chilled water, air and liquid cooling, heat rejection) for high-density compute

Demonstrated experience defining redundancy and resilience topologies and translating availability targets into design criteria

Hands-on experience with utility interconnection, substation design, and energization planning for large loads

Experience leading commissioning (Levels 1–5 / integrated systems testing) and facility turnover on mission-critical projects

Proven ability to lead engineering consultants, contractors, and internal technical staff, and to make and defend technical decisions with executives, customers, and partners

Strong constructability judgment and experience partnering with construction teams through design, procurement, and field execution

Excellent communication skills, with the ability to explain complex technical trade-offs clearly to non-technical stakeholders

Preferred Qualifications

Professional Engineer (PE) license strongly preferred

Experience with AI, HPC, or hyperscale data center design, including liquid-cooled and high-density rack deployments

Owner-side experience with a hyperscaler, colocation provider, or large infrastructure developer

Experience developing and governing engineering standards or Basis of Design programs across multiple sites

Familiarity with Uptime Institute Tier concepts, ASHRAE TC 9.9 guidelines, NEC/NFPA 70 and NFPA 70E, IEEE power system standards, and applicable energy codes

Master’s degree in engineering or an MBA

Experience in a fast-growth owner organization building in-house technical capability

This position may involve duties that require operation of a company vehicle or travel between job sites. As such, candidates must be insurable under CleanSpark's vehicle insurance policy.

CleanSpark is an Equal Opportunity Employer. It provides equal employment opportunities to all employees and applicants for employment and prohibits discrimination and harassment of any type without regard to race, color, religion, age, sex, national origin, disability status, genetics, protected veteran status, sexual orientation, gender identity or expression, or any other characteristic protected by federal, state, or local laws. This policy applies to all terms and conditions of employment, including recruiting, hiring, placement, promotion, termination, layoff, recall, transfer, leaves of absence, compensation, and training.